Technologies We Provide
Sustainable biomass technology
Dall Energy´s products are based on our own technologies which were developed, refined and patented over the past few decades.
Due to very low dust emission from the Dall Energy furnace our heating plants do not need bagfilters or an electro filter in that the flue gas condenser provides sufficient particle removal. The table below provides an overview of our furnace performance compared to a traditional grate solution and the European air emissions requirements.
Dust [mg/Nm3] (in EU)
NOx [mg/Nm3] (in EU)
CO [mg/Nm3]:
at 100 % Load
at 10 % Load
30
300
850
850
500 – 1000 out of furnace, or
100 – 125 after condensation.
200-300
< 600
Operation not possible
30 – 60 at the furnace outlet
10 – 20 after condensation.
100-200
< 10
< 20
The table above indicates the relevant Danish legal requirements for air emissions based on Order No. 751 of 28/05/2018 (cf. EU MCP Directive).
The requirements are defined at 273.15 K, 101.3 kPa and 6% O2 dry basis.
Dust [mg/Nm3] (in EU)
Required by Law: 30
Typical grate solution: 500 – 1000 out of furnace, or 100 – 125 with flue gas scrubber
Dall Energy solution
100 – 200
NOx [mg/Nm3] (in EU)
Required by Law: 300
Typical grate solution: 200 – 300
Dall Energy solution
100 – 200
CO [mg/Nm3] (in Denmark):
Required by Law: (100% load) 850
(10% load) 850
Typical grate solution: Operation not possible
Dall Energy solution
(100% load) < 10
(10% load) < 20
Above air emissions requirements are based on EU Directive 2015/2193 of 25 November 2015 (the EU MCP Directive) and requirements are defined at 273,15 K, 101,3 kPa, 6% O2 dry basis. Requirements for CO differ in between the individual EU countries and thus we have stated the Danish limits. DK: BEK nr 751 af 28/05/2018
In the city of Bogense 6,000 people get their heating from a special biomass oven. They are warmed by that. And I am warmed by the fact that the inventor of the oven has been awarded the European Inventor Award..."
Former Danish Prime Minister Lars Løkke Rasmussen